AI Assistant for Automation

The machine expert,
onboard the machine.

LinePilot is a local, 100% offline AI server installed directly on the production line. It answers in natural language — by voice or in chat — the questions of operators and engineers about the process, components, technical manuals and fault diagnosis.

  • Zero cloud
  • Zero data leaving the site
  • Voice + chat
  • Multilingual

What are you looking at?

The line is down. LinePilot queries the PLC, cross-checks the wiring diagram and pinpoints the fault in seconds: brand, spare-part code and terminals of the right component. Without it, the maintenance technician would waste precious time leafing through manuals to find the right wire.

Less diagnosis time, less downtime.

OP
Operator · 11:41
The press won't move
AI
LinePilot · 11:41
Status read from the PLC
AQ3/i_AbilPress Pressure enable / exclude selector +AQ3 FALSE
AQ3/o_KM_pompa Lubrication pump motor contactor command +AQ3 FALSE
AQ3/o_EV_Pres Pressure engagement solenoid valve command +AQ3 FALSE

PRESS SOLENOID VALVE — 340Y2 (solenoid valve)

  • Panel +AQ3 · sheet 340 (page 92)
  • Command: PLC output %Q212.3 (module 210A4)
  • Connections: terminals X4 · power supply 0DC
Diagnosis

PLC output %Q212.3 is FALSE — the actuator is not receiving the command. Interlocks NOT satisfied:

  • Pressure enable selector (%I212.6) = FALSE → TRUE required
  • Lubrication pump contactor (%Q212.0) = FALSE → TRUE required
  • also to be checked: M_PORTA_OK, M_EMERG_OK (guards, emergencies)
Suggested checks
  1. Set the pressure enable selector to ON and check its contact — Procedure: §18
  2. Check the lubrication pump contactor — Procedure: §14
  3. Check guards and emergencies (doors closed, e-stops reset)
⚠ Before operating apply LOTO (Section 0) and make sure the area is clear and safe.
Documents consulted

Component identified from the wiring diagram, I/O status read in real time from the PLC, diagnosis of the missing interlocks and verification procedures. With the sources cited, always.

OP
Operator · 09:17
I have a problem at the outfeed, I suspect it's the end-of-line photocell: could you tell me the brand and model so I can check if I have it in stock?
AI
LinePilot · 09:17
Status read from the PLC
AQ1/i_FTC_fineln End-of-line photocell, part present at the outfeed FALSE

END-OF-LINE PHOTOCELL — B12 · Sick WL12G-3B2531 · stock code EL-0417

  • Panel +AQ1 · sheet 118 (page 31)
  • PLC input %I3.4 (module 110A2)
  • Connections: terminals X2:14 (signal) · X2:15 (24VDC) · X2:16 (0V)
Signal check
  1. Block and clear the beam: the yellow LED on the photocell must switch and input %I3.4 change state — Procedure: §7 (Checking a PLC digital input)
  2. If the LED does not switch, clean the optics and the reflector and check the 24VDC on terminals X2:15/X2:16
  3. If the signal is still absent, perform the alignment — Procedure: §25 (Photocell adjustment)
Documents consulted

Brand, model and stock code from the bill of materials, connections from the wiring diagram, live reading of the PLC input and adjustment procedure. With the sources cited, always.

OP
Operator · 09:51
The infeed pump won't start
AI
LinePilot · 09:51
Status read from the PLC
AX7/i_th_Pompa1 Motor-protection circuit breaker, main tank pump 1 TRUE
AX7/o_KM_Pompa1 Tank pump 1 motor contactor command FALSE

INFEED PUMP — 1.1 KW / 2.66 A — 372M1 (motor)

  • Panel +AX7 · sheet 372 (page 108)
  • Connections: terminals X2:1, X2:2, X2:3 · power 2U1, 2V1, 2W1, PE

INFEED PUMP OVERLOAD (auxiliary contact 13-14) — 372Q1 (circuit breaker)

  • Panel +AX7 · sheet 372 (page 108)
  • Signal: PLC input %I218.2 (module 215A3) = TRUE
  • Connected to: 372KM1 (contactor 24VDC 3KW 1NO)
  • Spare part code: SIE.3RV2011-1DA10 (Siemens)

CONTACTOR 24VDC 3KW (1NO) — 372KM1 (contactor)

  • Panel +AX7 · sheet 372 (page 108)
  • Command: PLC output %Q218.5 (module 215A5) = FALSE
  • Connected to: 372Q1 (infeed pump overload, contact 13-14)
  • Spare part code: SIE.3RT2015-1BB41 (Siemens)
Diagnosis

The motor-protection circuit breaker is closed (%I218.2 = TRUE), but the command output %Q218.5 is FALSE: contactor 372KM1 is not energized and the motor is not receiving power.

Suggested checks
  1. Check the state of digital output %Q218.5 on the PLC — Procedure: §11
  2. Check contactor 372KM1 (energization and contacts) — Procedure: §21
  3. Measure the voltage at the terminals of motor 372M1 — Procedure: §2
⚠ Before every check, isolate and make safe (LOTO). Work on the electrical panel: qualified personnel only.
Documents consulted

Actuator identified from the wiring diagram, I/O status read in real time from the PLC, diagnosis of the missing command and verification procedures. With the sources cited, always.

OP
Operator · 11:44
check lubrication pressure switch
AI
LinePilot · 11:44
Status read from the PLC
AK2/i_Press_lu Lubrication circuit pressure control switch TRUE
AK4/i_Press_lu Lubrication circuit pressure control switch +AK4 FALSE

LUBRICATION PRESSURE SWITCH — 295S2 (probe)

  • Panel +AK2 · sheet 295 (page 84)
  • Signal: PLC input %I164.3 (module 280A4) = TRUE
  • Connections: terminals X5:4+, X5:5+, X5:5- (wire E164.3) · power 24V1

LUBRICATION PRESSURE SWITCH — 555S2 (probe)

  • Panel +AK4 · sheet 555 (page 146)
  • Signal: PLC input %I368.3 (module 540A4) = FALSE
  • Connections: terminals X5:4+, X5:5+, X5:5- (wire E368.3) · power 24V1
⚠ Work on the electrical panel. Operations on panels, terminal blocks, wiring and drives must be carried out only by qualified maintenance personnel, with the machine isolated and made safe (LOTO). If you are not authorized, contact maintenance.
Documents consulted

Two identical pressure switches on different panels: I/O status in real time from the PLC (one TRUE, one FALSE), identity and connections from the wiring diagram with panel, sheet and terminals. With the sources cited, always.

OP
Operator · 11:11
I've got a problem with the hatch actuator
AI
LinePilot · 11:11

Which one? Reply with the NUMBER (or the designator):

  1. 412KM1A — HATCH ACTUATOR reversing contactor (A) · +AQ2 (f.412)
  2. 412KM1C — HATCH ACTUATOR reversing contactor (C) · +AQ2 (f.412)
  3. 410Q2 — HATCH ACTUATOR OVERLOAD (auxiliary contact 13-14) · +AQ2 (f.410)
  4. 410M2 — HATCH ACTUATOR — 0,55 KW / 1,65 A · +AQ2 (f.410)
OP
Operator · 11:12
2
AI
LinePilot · 11:12
Status read from the PLC
%Q248.5 Tank door CLOSING contactor / solenoid valve command FALSE
%Q220.1 Auxiliaries run safety contactor command +AK1 (SIL3/PLe) TRUE

You have a problem with the hatch actuator reversing contactor (C): here are the details for diagnosis.

HATCH ACTUATOR reversing contactor (C) — 412KM1C (contactor)

  • Panel +AQ2 · sheet 412 (page 93)
  • Command: PLC output %Q248.5 (module 430A5) = FALSE
  • Connections: power 2U3, 2V3, 2W3, 0DC
  • Connected to: 412KM2 (hatch contactor feedback, contact 21-22) · 412KM1A (HATCH ACTUATOR reversing contactor A)

HATCH CONTACTOR FEEDBACK (contact 21-22 of 412KM2) — 412KM2 (contactor)

  • Panel +AQ2 · sheet 412 (page 93)
  • Command: PLC output %Q220.1 (module 430A2) = TRUE
  • Signal: PLC input %I205.2 (module 430A1) = TRUE
  • Connections: power 24V1
  • Connected to: 410Q2 (hatch actuator overload, auxiliary contact 13-14) · 412KM1A · 412KM1C
  • Spare part code: SIE.3RT2015-1BB42 (SIEMENS)
Field checks

⚠ Before every check: isolate and make safe (LOTO).

  1. Procedure 21 — Checking a contactor (on 412KM1C)
  2. Procedure 11 — Checking a PLC digital output (on 412KM1C)
  3. Guide me step by step (control circuit / coil)

Check the state of contactor 412KM2 that powers the hatch actuator reversing contactor (C) 412KM1C, making sure it is energized and that there are no breaks or damaged connections. Then physically check whether 412KM1C is able to close when energized.

⚠ Work on the electrical panel. Operations on panels, terminal blocks, wiring and drives must be carried out only by qualified maintenance personnel, with the machine isolated and made safe (LOTO). If you are not authorized, contact maintenance.
Documents consulted
OP
Operator · 11:12
Guide me step by step on 412KM1C (control)
AI
LinePilot · 11:12
GUIDE — 412KM1C — control

Take the multimeter to check whether the PLC is commanding the energization of the coil of contactor 412KM1C (+AQ2).

⚠ Panel OPEN and LIVE: qualified personnel only, maximum caution and PPE. Voltage measurements are taken live; continuity ONLY with the circuit isolated (LOTO).
Control circuit — 412KM1C

PLC output (live) — multimeter on V DC

  • terminals 4–A2 (wires A248.5–0DC)
  • Expected: 24VDC when the PLC commands (≈0 V if it doesn't command). PLC output %Q248.5 (module 430A5).

Voltage at the coil A1–A2 (live) — multimeter on V DC

  • terminals A1–A2 (wires A248.5–0DC)
  • Expected: 24VDC when the PLC commands (≈0 V if it doesn't command).

Series interlock contact (ISOLATED circuit) — multimeter on Ω

  • terminals 22–21
  • Expected: contact CLOSED at rest (~0 Ω).

Coil continuity A1–A2 (ISOLATED circuit) — multimeter on Ω

  • terminals A1–A2 (wires A248.5–0DC)
  • Expected: resistance NOT zero and NOT infinite (coil intact); ~0 Ω = shorted turns, ∞ = open.

Confirm with ok if everything is as expected, or indicate which measurement doesn't add up.

⚠ Work on the electrical panel. Operations on panels, terminal blocks, wiring and drives must be carried out only by qualified maintenance personnel, with the machine isolated and made safe (LOTO). If you are not authorized, contact maintenance.

Real multi-hop: from a vague request to disambiguation among 14 candidates, then diagnosis with the contactor feedback read from the PLC and finally the step-by-step guide with the multimeter. With the sources cited, always.

DigithON 2026

LinePilot is one of the finalist projects of DigithON 2026.

Why LinePilot

Knowledge doesn't retire

The line's know-how lives in dozens of manuals and diagrams and in the heads of a few experts. LinePilot makes it queryable by anyone, on any shift, in any language.

Shorter machine downtime

Guided diagnosis in seconds instead of hours leafing through PDFs: brand, model and spare part code of the right component, with the history of similar interventions.

Your data stays in the factory

No cloud, no external API: LLM, semantic search and voice run entirely on the server onboard the machine. It works even without an internet connection.

Features

🔌 100% offline

Everything local: language model, embeddings, speech recognition and synthesis. No data ever leaves the plant.

🎯 Never invent a code

LinePilot answers only from your line's documents and states when it doesn't know. A wrong spare part code is costly: that doesn't happen here.

📄 Sources always cited

Every answer indicates the source document and page: verifiable in one click.

🎙️ Hands-free voice

Speak and listen: speech recognition and synthesis, designed for use on the line with gloves on.

⚡ Answers in seconds

Response streaming and a search indicator: designed for production timing, not office timing.

📚 Multilingual manuals

Datasheets in English, manuals in German, SOPs in Italian: LinePilot indexes them all and answers in the operator's language.

🔌 PLC connection

Direct connection to the line PLC in read-only: LinePilot sees the real state of inputs and outputs, without ever writing and without interfering with the machine cycle.

📈 Real-time diagnosis

It cross-references the PLC software logic with the live I/O status: it pinpoints the missing interlocks and tells you why an actuator won't start, while the fault is happening.

🔗 Connection to the company ERP

Optional integration with the management system for the spare-parts warehouse: stock level and location of the component directly in the answer, always on the local network.

How it works

  1. 1

    Ask a question

    In chat or by voice, as you would ask an expert colleague. Even complex questions that span multiple documents.

  2. 2

    Get the answer with the sources

    LinePilot retrieves the relevant passages, links manual, diagram and bill of materials, and answers citing document and page.

  3. 3

    Process and live data too

    It also answers about the production process and, with the optional connections, about the I/O status read from the PLC and the availability of spare parts in the warehouse (ERP).

Architecture

An AI server installed at the line that runs 100% offline: language models, semantic search, speech recognition and synthesis all run locally on an industrial PC with a dedicated GPU. No cloud, no external APIs, no data leaving the company.

Local generative AILanguage models run on the line server
Semantic searchFinds the answer in the manuals and diagrams by meaning, not by exact word
Offline voiceSpeech recognition and synthesis without cloud
HardwareIndustrial PC with dedicated GPU, sized to the complexity of the plant
NetworkPlant LAN only, internet not required
Optional integrationsRead-only PLC · PLC program analysis · spare-parts warehouse (ERP)

Machine integration

Every installation is engineered on the specific machine, so the assistant knows the plant it works on inside out.

📚 Know-how and documentation

We index technical manuals, wiring diagrams, datasheets, bills of materials, SOPs and internal procedures. Going forward, the PC will ship pre-configured for the line.

🎯 Verifiable sources

Every answer reports the source document and page. If the information is not in the documentation, LinePilot says so instead of making it up.

🧰 Guided troubleshooting

Guides the operator step by step through the diagnosis, down to hands-on checks such as multimeter measurements, with LOTO and PPE reminders.

🔒 Read-only PLC

Reads I/O status, alarms and operating states made available in an exchange DB. It never writes and never interferes with the machine cycle: the existing logic is untouched, the exchange DB is a small addition agreed with you.

🧠 PLC program analysis

From the up-to-date PLC program, LinePilot cross-checks the logic against live I/O status: it finds the missing interlocks that block an operation and answers on the plant's real situation.

📈 On the roadmap: predictive maintenance

For example by matching contactor and relay data with the ON/OFF cycles actually performed, to anticipate wear before a failure.

PLC compatibility

ProtocolCompatibility
OPC UAMulti-vendor: any PLC or gateway with an OPC UA server
S7 (Ethernet)Siemens S7-300 / 400 / 1200 / 1500
Modbus TCPSchneider Electric Modicon (M221, M241, M251, M340, M580) and other PLCs with Modbus TCP
FINS (UDP / TCP)Omron CJ / CS, NJ / NX
EtherNet/IP (CIP)Rockwell / Allen-Bradley ControlLogix, CompactLogix, SLC 500

Always read-only, no changes to the PLC program. Your PLC is not listed? Let's talk: new protocols are added on request.

How to get started

First see LinePilot at work, then on your documents, finally at the line.

  1. 1

    Intro call and demo

    In a remote call we show you LinePilot on a machine with already-engineered documentation: how it answers, cites sources and guides the operator through the diagnosis.

  2. 2

    Demo on your machine

    Under a non-disclosure agreement, you send us the documentation (wiring diagrams, manuals, optionally the PLC program) and we engineer it to show you LinePilot on your real documents. This is dedicated work, so it is paid, with the cost deductible if you continue with the pilot. Scope and costs are defined together.

  3. 3

    Pilot project

    Installation of the industrial PC at the line, with an optional read-only PLC connection. 100% offline: no data leaves the plant.

Book an intro call

Tell us about your line: we'll set up a remote call and show you LinePilot at work on a real machine.

or write to us at info@linepilot.it